    During our inspection, a Red Blood Cell component was identified as being in quarantine according to an electronic inventory inquiry on January 30, 2013. However, the component could not be located in the expected physical quarantine location. After the discrepancy was identified by our investigators, a search was initiated and the component was found in the discard bin. The component had been physically discarded without maintaining a record of the discard as required by TS 500-2, Final Disposition of Blood Components. Failure to check input to and output from the computer or related system of formulas or other records or data for accuracy [21 CFR 211.68(b)].